203 Articles  2254 Elements

Drawing force in transition zone

7.2
Prismatic drawn part
Fig. 1
Deformation zones during prismatic deep drawing
1 Corner area 2 Transition zone 3 Straight drawn part side A Length of transition zone b Straight drawn part side

First, the tensile stress in the corner of the drawn part is calculated. The tensile stress on the straight side of the drawn part is then calculated. Finally, the drawing force in the transition zone can be determined using the following formula:

Eqn. 1
\require{color}\definecolor{myred}{RGB}{255,0,0} F_{\color{myred}U}=n\cdot\Delta\sigma\cdot s_{\color{myred}0}
FU=0.5kN 
Numbern = 1
Sheet thicknesss0 = 1mm
Tension differenceΔσ = 500MPa
Calc 1
Drawing Force Transition Zone 35
35
Strackerjahn, W.Die Voraussage des Versagensfalls beim Tiefziehen rechteckiger TeileDissertationHannover1982
© 2023 4Ming e.K.
Kdia v1.3.1
4Ming® Prototypes, tools, die cushions, presses
Management consulting, process development & process optimization
Interactive Sheet Metal Forming Technical Guide